Safetybox fireproof cabinet storage and charging space for lithium batteries
W: 810, D: 660, H: 520 (mm)|Article code: 48-11894
Price per item
:
€ 3.713,45
€ 4.493,27 inc. VAT
Quantity
Select a version of this product
| Delivery time | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
Storage for lithium batteries | 810 | 520 | 580 | 174 | 48-11890 | € 2.253,95 | 11 November delivered | |
|
storage and charging space for lithium batteries | 780 | 500 | 580 | 174 | 48-11892 | € 2.971,45 | 11 November delivered | |
|
storage and charging space for lithium batteries | 810 | 520 | 660 | 174 | 48-11894 | € 3.713,45 | 11 November delivered | |
|
storage and charging space for lithium batteries | 880 | 520 | 660 | 174 | 48-11896 | € 4.791,95 | 11 November delivered |
Specifications
Dimensions & Weight
Width (mm)
810
Internal width (mm)
730
Height (mm)
520
Internal height (mm)
450
Depth (mm)
660
Internal depth (mm)
530
Weight (kg)
82
Capacity & Load Bearing
Volume (ltr)
174
Materials & Construction
Material
steel
Colour
grey
Ral colour
7035, 2004
Functionality & Features
Type
fireproof cabinet
Implementation
storage and charging space for lithium batteries
Additional specifications
60 minutes fire resistant
Certifications & Safety
Certification
TÜV Nord
Product Details
Article code:
48-11894
Article arrangement
New
EAN Code (Gtin):
8719424254334
Description
Premium 8/5 1-phase battery charging cabinet - lockEX
Powered smoke detector, power supply in the cabinet with socket strip(s), technical ventilation, power cut-off in the event of heat development or via door contact switch, power cut-off also in the event of smoke detection, acoustic warning tone, potential-free output on the outside of the cabinet for connection to the company's internal building management system, 12 V connection option for e.g. accessory combination alarm unit (optical & acoustic)
- Power supply via 6-socket power strip (3500 W, 16 A)
- Heat dissipation during charging by fan
- Charging current interrupted when doors are opened (door contact switch)
- Charging stop in the event of a fault or accident
- Closure of the air inlet and outlet openings by thermocouples
- Fire protection is a high priority when storing and charging lithium batteries.
- Equipped with important safety devices, the fire consequences of these energy storage systems can be reduced to a minimum and operational safety significantly increased.
- charge and/or store several lithium batteries in the cabinet
- Early alarm in the event of damage
- the relevant safety rules for charging lithium batteries are observed
- ideal for shielding batteries from the stored stock during the charging process
- Can also be used as an underbench cabinet under the workbench
- TÜV NORD Group verification through the latest M02/22 test program with real battery fire tests and induced gas explosions (link to certificate)
- MPA-tested fire resistance over 60 minutes from the inside to the outside in accordance with DIN EN 1363-1
- Construction with non-combustible, fire-resistant components
- NEW: Spring-based lockEX door interlock for controlled pressure relief in the event of explosions
- Special fire protection seals prevent flames from escaping
- Cold smoke-tight closure system of the openings
- Transportable for positioning at the installation site
- double-leaf, lockable doors with sturdy locking system & suspension
- door finish in orange, similar to RAL 2004; body in gray, similar to RAL 7035
Powered smoke detector, power supply in the cabinet with socket strip(s), technical ventilation, power cut-off in the event of heat development or via door contact switch, power cut-off also in the event of smoke detection, acoustic warning tone, potential-free output on the outside of the cabinet for connection to the company's internal building management system, 12 V connection option for e.g. accessory combination alarm unit (optical & acoustic)
- Power supply via 6-socket power strip (3500 W, 16 A)
- Heat dissipation during charging by fan
- Charging current interrupted when doors are opened (door contact switch)
- Charging stop in the event of a fault or accident
- Closure of the air inlet and outlet openings by thermocouples
- Fire protection is a high priority when storing and charging lithium batteries.
- Equipped with important safety devices, the fire consequences of these energy storage systems can be reduced to a minimum and operational safety significantly increased.
- charge and/or store several lithium batteries in the cabinet
- Early alarm in the event of damage
- the relevant safety rules for charging lithium batteries are observed
- ideal for shielding batteries from the stored stock during the charging process
- Can also be used as an underbench cabinet under the workbench
- TÜV NORD Group verification through the latest M02/22 test program with real battery fire tests and induced gas explosions (link to certificate)
- MPA-tested fire resistance over 60 minutes from the inside to the outside in accordance with DIN EN 1363-1
- Construction with non-combustible, fire-resistant components
- NEW: Spring-based lockEX door interlock for controlled pressure relief in the event of explosions
- Special fire protection seals prevent flames from escaping
- Cold smoke-tight closure system of the openings
- Transportable for positioning at the installation site
- double-leaf, lockable doors with sturdy locking system & suspension
- door finish in orange, similar to RAL 2004; body in gray, similar to RAL 7035